DESCRIPTION
For a description of the inverter Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A78 | 202 | Malfunction (short circuit) in the motor inverter inside the inverter with converter assembly |
|
MONITOR DESCRIPTION
The MG ECU monitors the motor inverter electric current. If the current exceeds the threshold for a specified period of time, the power management control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
| Related DTCs | P0A78 (INF 202): MFIV detection (Short circuit malfunction) |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
TYPICAL MALFUNCTION THRESHOLDS
| TMC's intellectual property | - |
COMPONENT OPERATING RANGE
| Power management control ECU | DTC P0A78 (INF 202) is not detected |
CONFIRMATION DRIVING PATTERN
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off.
Turn the power switch on (IG) and check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc).
Turn the power switch on (READY) and turn the Techstream on. [A]
With the shift lever in P, wait for several seconds.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [B]
Check that permanent DTCs are cleared.
If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.
Tech Tips
If a permanent DTC is output, the system is malfunctioning.
If no permanent DTC is output, the system is normal.
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
DTC P0A78-202 is stored after any of DTCs P0A78-113, 128, 284, 286, 287, 505, 506, 806, 807 and 808 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.
Depending on the conditions in which the vehicle is being operated when a short circuit occurs in the inverter with converter assembly, the hybrid vehicle transaxle assembly may be affected. As this DTC is stored if a short circuit occurs in the inverter with converter assembly, it is necessary to perform a road test to check the hybrid vehicle transaxle assembly. If problems are found, replace the malfunctioning parts.
After completing the repair, including the repair of previously output DTCs, drive the vehicle at a speed of approximately 40 km/h (25 mph) for 1 minute and check that DTC P0A90-251 (Drive Motor "A" Performance) is not output. If DTC P0A90-251 (Drive Motor "A" Performance) is output, replace the hybrid vehicle transaxle assembly.
PROCEDURE
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
Disconnect the generator cable and motor cable from the inverter with converter assembly.
| *1 | Shield Ground |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the generator cable and motor cable.
Install the upper inverter cover (generator cable side) and upper inverter cover (motor cable side).
| NG |
|
| OK |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Check the other DTCs that were output together with DTC P0A78-202.
| Result | ||||
|---|---|---|---|---|
|
Note
DTC P0A78-202 is stored after any of DTCs P0A78-113, 128, 284, 286, 287, 505, 506, 806, 807 and 808 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.
| NEXT |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here
CHECK MOTOR CABLE
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable Click here.
| *1 | Shield ground |
| *a | Motor Cable (Inverter with Converter Assembly Side) |
| *b | Motor Cable (Hybrid Vehicle Transaxle Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Install the motor cable.
| NG |
|
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) Click here |
| OK |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
| NEXT |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Check the other DTCs that were output together with DTC P0A78-202.
| Result | ||||
|---|---|---|---|---|
|
Note
DTC P0A78-202 is stored after any of DTCs P0A78-113, 128, 284, 286, 287, 505, 506, 806, 807 and 808 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.
| NEXT |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the motor cable from the hybrid vehicle transaxle assembly.
| *a | Component without motor cable connected (Hybrid Vehicle Transaxle Assembly) |
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
Tech Tips
If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (° C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the motor cable.
| NG |
|
REPLACE MOTOR CABLE Click here |
| OK |
|
REPLACE MOTOR CABLE
| NEXT |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Check the other DTCs that were output together with DTC P0A78-202.
| Result | ||||
|---|---|---|---|---|
|
Note
DTC P0A78-202 is stored after any of DTCs P0A78-113, 128, 284, 286, 287, 505, 506, 806, 807 and 808 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.
| NEXT |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here
REPLACE MOTOR CABLE
| NEXT |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY
| NEXT |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY
| NEXT |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Check the other DTCs that were output together with DTC P0A78-202.
| Result | ||||
|---|---|---|---|---|
|
Note
DTC P0A78-202 is stored after any of DTCs P0A78-113, 128, 284, 286, 287, 505, 506, 806, 807 and 808 are stored. After troubleshooting and repairing DTC P0A78-202, be sure to troubleshoot all the other DTCs.
| NEXT |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here