HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A0D-350, P0A0D-351

DTC Code DTC Name
P0A0D-350 High Voltage System Inter-Lock Circuit High
P0A0D-351 High Voltage System Inter-Lock Circuit High

DESCRIPTION


DTC No. INF Code DTC Detection Condition Trouble Are
P0A0D 350 Operating any of the safety devices with the vehicle stopped (ILK signal is ON) and turning the power switch on (IG)
  • Wire harness or connector

  • Power management control ECU

  • Service plug grip

  • Inverter with converter assembly

  • No. 4 engine wire

  • Upper inverter cover

351 Interlock signal line opens (ILK signal is ON) while the vehicle is being driven

WIRING DIAGRAM

A01HT0TE01

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A0D only is output. A
      P0A1D is output B
    5. Turn the power switch off.


    B
    A
  2. CLEAR DTC


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Read and record the DTCs and freeze frame data.

    5. Clear DTCs and freeze frame data.

    6. Turn the power switch off.


    NEXT
  3. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the Techstream to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A0D-350 or P0A0D-351 is output again. A
      Neither P0A0D-350 or P0A0D-351 is output again. B
    5. Turn the power switch off.


    B
    A
  4. CHECK SERVICE PLUG GRIP

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check if the service plug grip is installed correctly.

      Tech Tips


      • For the removal and installation procedures Click here.

      • P0A0D-350 is also set if the power switch is turned on (IG) with the service plug grip removed. Confirm the conditions when the malfunction occurred.


    NG
    OK
  5. CHECK UPPER INVERTER COVER (GENERATOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HTG6

      Check if the upper inverter cover (generator cable side) of the inverter with converter assembly is installed correctly.

      OK
      The upper inverter cover (generator cable side) is installed correctly.

    NG
    OK
  6. CHECK UPPER INVERTER COVER (MOTOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HUQS

      Check if the upper inverter cover (motor cable side) of the inverter with converter assembly is installed correctly.

      OK
      The upper inverter cover (motor cable side) is installed correctly.

    NG
    OK
  7. CHECK CONNECTOR COVER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HU0Q

      Check if the connector cover assembly of the inverter with converter assembly is installed correctly.

      OK
      The connector cover assembly is installed correctly.

    NG
    OK
  8. CHECK NO. 4 ENGINE WIRE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HVSP

      Check if the No. 4 engine wire (air conditioning harness) is connected correctly.

      OK
      The No. 4 engine wire (air conditioning harness) connector is connected correctly.

    NG
    OK
  9. CHECK POWER MANAGEMENT CONTROL ECU

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from the inverter with converter assembly.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01HW05E02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A14-16 (ILKI) - Body ground Power switch on (IG) 11 to 14 V

      Note

      Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Connect the inverter with converter assembly connector.


    NG
    OK
  10. CHECK INVERTER WITH CONVERTER ASSEMBLY (INTERLOCK)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from the inverter with converter assembly.

    3. A01HUUOE02
      Text in Illustration
      *a

      Component without harness connected

      (Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-16 (ILKI) - A14-5 (ILKO) Power switch off Less than 10 Ω

      Note

      Do not remove the upper inverter cover, connector cover assembly and No. 4 engine wire.

    4. Connect the inverter with converter assembly connector.


    NG
    OK
  11. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - BODY GROUND)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from the inverter with converter assembly.

    3. Install the service plug grip.

    4. A01HW05E03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-5 (ILKO) - Body ground Power switch off Below 1 Ω
    5. Remove the service plug grip.

    6. Connect the inverter with converter assembly connector.


    NG
    OK
  12. CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CIRCUIT)


    1. Check the connections of each connector.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.

    NG
    OK
  13. CHECK SERVICE PLUG GRIP


    1. Remove the service plug grip.

    2. A01HT2VE02
      Text in Illustration
      *1 Service Plug Grip

      Check the condition of the service plug grip interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    3. Install the service plug grip.


    NG
    OK
  14. CHECK CONNECTOR CONNECTION CONDITION (INTERLOCK CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HUCEE01
      Text in Illustration
      *1 Interlock Connector

      Check that the interlock connector at the service plug grip installation socket is connected correctly.

      OK
      The connector is connected correctly.

    NG
    OK
  15. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - SERVICE PLUG GRIP)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from the inverter with converter assembly.

    3. Disconnect connector r2 from the service plug.

    4. A01HSARE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Front view of wire harness connector

      (to Service Plug Grip)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-5 (ILKO) - r2-1(ILK) Power switch off Below 1 Ω
    5. Connect the service plug grip connector.

    6. Connect the inverter with converter assembly connector.


    NG
    OK
  16. CHECK UPPER INVERTER COVER (GENERATOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HTG6

      Remove the upper inverter cover (generator cable side) from the inverter with converter assembly.

    3. A01HTY0E01
      Text in Illustration
      *1 Upper Inverter Cover (Generator Cable Side)

      Check the condition of the upper inverter cover (generator cable side) interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    4. Install the upper inverter cover (generator cable side) to the inverter with converter assembly.


    NG
    OK
  17. CHECK UPPER INVERTER COVER (MOTOR CABLE SIDE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HUQS

      Remove the upper inverter cover (motor cable side) from the inverter with converter assembly.

    3. A01HTY0E01
      Text in Illustration
      *1 Upper Inverter Cover (Motor Cable Side)

      Check the condition of the upper inverter cover (motor cable side) interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    4. Install the upper inverter cover (motor cable side) to the inverter with converter assembly.


    NG
    OK
  18. CHECK CONNECTOR COVER ASSEMBLY

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HU0Q

      Remove the connector cover assembly from the inverter with converter assembly.

    3. A01HSBUE05
      Text in Illustration
      *1 Connector Cover Assembly

      Check the condition of the connector cover assembly interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.

      Tech Tips

      The connector cover assembly is not available separately. If it requires replacement, replace the inverter with converter assembly.

    4. Install the connector cover assembly to the inverter with converter assembly.


    NG
    OK
  19. CHECK NO. 4 ENGINE WIRE (NO. 4 ENGINE WIRE CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01HVSP

      Disconnect the No. 4 engine wire (air conditioning harness) from the inverter with converter assembly.

    3. A01HU2RE01
      Text in Illustration
      *1 No. 4 engine wire (air conditioning harness)

      Check the No. 4 engine wire (air conditioning harness) interlock.

      OK
      Dirt or foreign matter has not entered the connection, and there is no evidence of contamination.
    4. Connect the No. 4 engine wire (air conditioning harness) to the inverter with converter assembly.


    NG
    OK
  20. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - POWER MANAGEMENT CONTROL ECU)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect connector A14 from the inverter with converter assembly.

    3. Disconnect connector A38 from the power management control ECU.

    4. A01HSBTE01
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A14-16 (ILKI) - A38-32 (ILK) Power switch off Below 1 Ω
    5. Connect the power management control ECU connector.

    6. Connect the inverter with converter assembly connector.


    NG
    OK