ROOF DRIP SIDE FINISH MOULDING INSTALLATION


  1. INSTALL ROOF DRIP SIDE FINISH MOULDING CLIP

    Note


    • If reusing the clips, do not remove the double-sided tape remaining on the clips and where the clips will be installed on the body.

    • If installing new clips, remove the double-sided tape remaining where the clips will be installed on the body and clean the body with a non-residue solvent.


    1. A01EJUYE01

      Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to new roof drip side finish moulding clips.

      Tech Tips

      Adhesive strength (tensile strength): 13.7 MPa (140 kgf/cm2) or more (when the temperature is 23°C (73°F).)

    2. Press and install the 2 roof drip side finish moulding clips.

    3. A01EINOE01

      Install the clips to the positions on the roof panel shown in the illustration. Determine the locations and firmly press and install the 2 roof drip side finish moulding clips after lightly applying adhesive (3M DP-105 or equivalent).

      Standard Dimension
      Item Dimension
      A 4.9 mm (0.193 in.)
      B 8.4 mm (0.331 in.)
      C 2.1 mm (0.0827 in.)
      D 3.0 mm (0.118 in.)
      E 3.0 mm (0.118 in.)
      F 5.6 mm (0.221 in.)
      G 10.4 mm (0.409 in.)
    4. Install the roof drip center side finish moulding when 20 minutes or more have elapsed after pressing and installing the 2 roof drip side finish moulding clips.

      Tech Tips


      • Initial hardening time: 20 minutes

      • Complete hardening time: 48 hours

  2. INSTALL ROOF DRIP CENTER SIDE FINISH MOULDING


    1. A01EJSK

      Engage the 2 clips and install the roof drip center side finish moulding as shown in the illustration.