AUTOMATIC LIGHT CONTROL SENSOR REMOVAL


  1. REMOVE DEFROSTER NOZZLE GARNISH


    1. A01EJ5GE01

      Pull the defroster nozzle garnish in the direction indicated by the arrow to disengage the 4 clips, 6 claws and 6 guides.

    2. A01EJEE

      Disconnect the connector and remove the defroster nozzle garnish.

  2. REMOVE AUTOMATIC LIGHT CONTROL SENSOR


    1. A01EJL4

      Disengage the 2 claws and remove the automatic light control sensor.