POWER BACK DOOR MAIN SWITCH INSPECTION


  1. INSPECT POWER BACK DOOR MAIN SWITCH

    A01EMA9E03

    1. Check that the switch function.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        6 (E) - 9 (UL) Free Below 1 Ω
        6 (E) - 9 (UL) Pushed 10 kΩ or higher

        If the result is not as specified, replace the switch.

    2. Check that the switch illuminates.


      1. Apply battery voltage to the power back door main switch and check that the switch illuminates.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 8 (ILL+)

        Battery negative (-) → 7 (ILL-)

        Illuminates

        If the result is not as specified, replace the switch.