RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
Start up the engine.
Turn the A/C switch on.
Operate the cooler compressor at an engine speed of approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant. This causes most of the compressor oil from the various components of the A/C system to collect in the A/C compressor.
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE AIR CONDITIONING PRESSURE SENSOR
Disconnect the connector.
Remove the air conditioning pressure sensor.