ACTUATOR CHECK
Start the engine and warm it up.
Perform the indicator check Click here.
| *1 | Air Conditioning Control Assembly |
Press the recirculation/fresh switch to perform the actuator check.
Tech Tips
Be sure to perform the actuator check after starting the engine.
| *1 | Accessory Meter Assembly |
| *2 | Display Code |
As the actuator check is repeated from steps 1 to 10 at 1 second intervals, check the temperature and air flow visually and by hand.
Tech Tips
The display blinks at 1 second intervals in the step operation.
Press the OFF switch to finish panel diagnosis.
Press the AUTO switch to enter sensor check mode.
| Step No. | Display Code | Condition | ||||
|---|---|---|---|---|---|---|
| Blower Level | Air Mix Damper | Airflow Vent | Air Inlet Damper | Compressor | ||
| 1 | 0 | 0 | 0% open | FACE | FRESH | off |
| 2 | 1 | 1 | 0% open | FACE | FRESH | off |
| 3 | 2 | 17 | 0% open | FACE | RECIRCULATION/FRESH | on |
| 4 | 3 | 17 | 0% open | FACE | RECIRCULATION | on |
| 5 | 4 | 17 | 50% open | B/L | RECIRCULATION | on |
| 6 | 5 | 17 | 50% open | B/L | RECIRCULATION | on |
| 7 | 6 | 17 | 50% open | FOOT | FRESH | on |
| 8 | 7 | 17 | 100% open | FOOT-0 | FRESH | on |
| 9 | 8 | 17 | 100% open | F/D | FRESH | on |
| 10 | 9 | 31 | 100% open | DEF | FRESH | on |
| *1 | Air Conditioning Control Assembly |
If the steps are difficult to read because they change automatically, press the MODE switch to display the steps one at a time so that they can be read easily. The items are displayed step by step each time the MODE switch is pressed.
Tech Tips
Press the OFF switch to finish panel diagnosis.
Press the recirculation/fresh switch to enter sensor check mode.