ACCESSORY METER REMOVAL


  1. REMOVE DEFROSTER NOZZLE GARNISH


    1. A01EJ5GE01

      Pull the defroster nozzle garnish in the direction indicated by the arrow to disengage the 4 clips, 6 claws and 6 guides.

    2. A01EJEE

      Disconnect the connector and remove the defroster nozzle garnish.

  2. REMOVE ACCESSORY METER ASSEMBLY (w/o Rear View Monitor System)


    1. A01EMLD

      Remove the 2 bolts.

    2. Disengage the 2 clips.

    3. A01EJ67

      Disengage the 2 clamps.

    4. Disconnect the connector and remove the accessory meter assembly.

  3. REMOVE ACCESSORY METER ASSEMBLY (w/ Rear View Monitor System)


    1. A01EJPO

      Remove the 2 bolts.

    2. Disengage the 2 clips.

    3. A01EJLQ

      Disengage the 2 clamps.

    4. Disconnect the connectors and remove the accessory meter assembly.