METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG2 when the ignition switch is turned to ON, the indicator will not operate.

WIRING DIAGRAM

A01ELZYE01

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)


    1. A01EM16E07
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Disconnect the E2 connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E2-24 (ES) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      E2-13 (IG+) - Body ground Ignition switch ON 11 to 14 V
      E2-1 (B2) - Body ground Always 11 to 14 V
      E2-14 (B) - Body ground Always 11 to 14 V

    NG
    OK