NAVIGATION SYSTEM (for Navigation Receiver Type) AVC-LAN Circuit

DESCRIPTION

Each unit of the navigation system connected to the AVC-LAN (communication bus) transfers switch signals using the AVC-LAN.

If a short to +B or short to ground occurs in the AVC-LAN, the navigation system will not function normally because communication is not possible.

WIRING DIAGRAM

A01EJLJE45

INSPECTION PROCEDURE

Note

Depending on the parts that are replaced during vehicle inspection or maintenance, performing initialization, registration or calibration may be needed. Refer to Precaution for Navigation System Click here.

Tech Tips

The navigation receiver assembly is the master unit.

PROCEDURE


  1. INSPECT NAVIGATION RECEIVER ASSEMBLY


    1. Remove the navigation receiver assembly.

    2. A01EMIDE19
      Text in Illustration
      *a

      Component without harness connected

      (Navigation Receiver Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      7 (TX1+) - 8 (TX1-) Always 60 to 80 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (NAVIGATION RECEIVER ASSEMBLY - STEREO COMPONENT AMPLIFIER ASSEMBLY)


    1. Disconnect the E40 navigation receiver assembly connector.

    2. Disconnect the E14 stereo component amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E14-8 (TX+) - E40-7 (TX1+) Always Below 1 Ω
      E14-7 (TX-) - E40-8 (TX1-) Always Below 1 Ω
      E14-8 (TX+) - Body ground Always 10 kΩ or higher
      E14-7 (TX-) - Body ground Always 10 kΩ or higher

    NG
    OK
  3. INSPECT MALFUNCTIONING PARTS


    1. Disconnect and reconnect each slave unit one by one until the master unit returns to normal operation.

      Tech Tips


      • Check all slave units.

      • If disconnecting a slave unit causes the master unit to return to normal operation, the slave unit is defective and should be replaced.

      OK
      Master unit returns to normal operation.

    NG
    OK