VACUUM SWITCHING VALVE (for ACIS) INSPECTION


  1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)


    1. A01EK9IE02
      Text in Illustration
      *1 Body Ground

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 37 to 44 Ω
      1 - Body ground Always 1 MΩ or higher
      2 - Body ground

      If the result is not as specified, replace the air cleaner assembly.

    2. Check the vacuum switching valve operation.


      1. A01EJXYE03
        Text in Illustration
        *1 Port E
        *2 Air
        *3 Filter

        When vacuum is applied to port E, check that air is sucked into the filter.

        If the result is not as specified, replace the air cleaner assembly.

      2. A01EL09E03
        Text in Illustration
        *1 Air
        *2 Port F
        *3 Port E

        Apply battery voltage across the terminals. When vacuum is applied to port F, check that air is sucked into port E.

        If the result is not as specified, replace the air cleaner assembly.