KNOCK SENSOR INSTALLATION


  1. INSTALL KNOCK SENSOR


    1. A01EKXCE01

      Install the sensor with the bolt so that the sensor is angled as shown in the illustration.

      Torque:
      20 N*m  { 204 kgf*cm, 15 ft.*lbf }

      Note

      The acceptable installation angle of the sensor is between 7° upward and 10° downward from the horizontal position.

    2. Connect the sensor connector.

  2. INSTALL INTAKE MANIFOLD


    1. Install the intake manifold Click here.