| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84°C (176 to 183°F) |
| Standard valve lift | 10 mm (0.394 in.) or more at 95°C (203°F) |
| Standard current (w/o Towing package) | ||
| Item | Condition | Specified Condition |
| No. 1 cooling fan motor | 12 V, 20°C (68°F) | 11.8 to 14.8 A |
| No. 2 cooling fan motor | 12 V, 20°C (68°F) | 7.9 to 10.9 A |
| Standard current (w/ Towing package) | ||
| Item | Condition | Specified Condition |
| No. 1 cooling fan motor | 12 V, 20°C (68°F) | 7.9 to 10.9 A |
| No. 2 cooling fan motor | 12 V, 20°C (68°F) | 7.9 to 10.9 A |
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator reservoir cap | Standard value (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 17 psi) |
| Minimum standard value (after using cap) | 79 kPa (0.8 kgf/cm2, 11.4 psi) |