BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS SERVICE DATA

Stop Light Control (BRK) Relay
Tester Connection Switch Condition Specified Condition
3 - 4 Voltage is not applied between terminals 1 and 2 Below 1 Ω
3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
3 - 4 Voltage is applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω
VSC OFF Switch
Tester Connection Switch Condition Specified Condition
6 (+) - 3 (E) Switch is pushed in Below 1 Ω
6 (+) - 3 (E) Switch is not pushed in 10 kΩ or higher
Brake Pedal Load Sensing Switch
Tester Connection Switch Condition Specified Condition
2 (FSW+) - 1(GND) Brake pedal load sensing switch OFF (Brake pedal depressed) 950 to 1050 Ω
2 (FSW+) - 1(GND) Brake pedal load sensing switch ON (Brake pedal released) 203 to 223 Ω