| DTC Code | DTC Name |
|---|---|
| P1364 | "C" Camshaft Position Actuator Circuit Open, Low, High Bank1 |
| P1365 | "C" Camshaft Position Actuator Circuit Open, Low, High Bank2 |
DESCRIPTION
Refer to DTC P0010 Click here.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P1364 | Engine is running, open or short in VTM1 and VTP1 terminals of camshaft timing control motor is detected for 3 seconds (1 trip detection logic) |
|
| P1365 | Engine is running, open or short in VTM2 and VTP2 terminals of camshaft timing control motor is detected for 3 seconds (1 trip detection logic) |
|
MONITOR DESCRIPTION
This DTC is output when a power supply malfunction, diagnostic signal malfunction or motor operation signal malfunction is detected in the intake side camshaft timing control motor. The camshaft timing control motor is equipped with a self diagnostic function, which is used to send diagnostic signals (VTM) to the ECM. If the ECM receives a VTP or VTM open signal, a DTC is output immediately (1 trip detection logic).
If the engine is idled for 10 seconds, a DTC is detected.
WIRING DIAGRAM
Refer to DTC P1360 Click here.
INSPECTION PROCEDURE
Tech Tips
Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
INSPECT VVT RELAY (VVT LH, VVT RH)
Remove the VVT LH relay or VVT RH relay from the engine room No. 2 relay block.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE VVT RELAY (VVT LH, VVT RH) |
| OK |
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE VOLTAGE)
Disconnect the E9 or E19 camshaft timing control motor.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | |||||||
|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE HARNESS OR CONNECTOR (VVT RELAY (VVT LH, VVT RH) - CAMSHAFT TIMING CONTROL MOTOR) |
| OK |
|
CHECK HARNESS AND CONNECTOR
Turn the engine switch off.
Disconnect the E9 or E19 camshaft timing control motor.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||
|---|---|---|---|---|---|---|---|
|
| NG |
|
INSPECT CAMSHAFT TIMING CONTROL MOTOR (BANK 1 OR BANK 2) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (CAMSHAFT TIMING CONTROL MOTOR - ECM)
Disconnect the E10 or E18 camshaft timing control motor connector.
Disconnect the E2 or E4 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Standard resistance (Check for short) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE CAMSHAFT TIMING CONTROL MOTOR (BANK 1 OR BANK 2)
Replace the camshaft timing control motor Click here.
| NEXT |
|
CHECK WHETHER DTC OUTPUT RECURS Click here |
INSPECT CAMSHAFT TIMING CONTROL MOTOR (BANK 1 OR BANK 2)
Check that the 3 bolts of the camshaft timing control motor are tightened securely.
| NG |
|
TIGHTEN BOLT Click here |
| OK |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (VVT RELAY (VVT LH, VVT RH) - CAMSHAFT TIMING CONTROL MOTOR)
| NEXT |
|
CHECK WHETHER DTC OUTPUT RECURS
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the tester ON.
Clear the DTCs Click here.
Start the engine and allow the engine idle for 10 seconds or more.
Enter the following menus: Powertrain / Engine / DTC.
Read DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO DTC CHART Click here |
| A |
|
END