| DTC Code | DTC Name |
|---|---|
| P1362 | "B" Camshaft Position Actuator Circuit Open, Low, High Bank1 |
| P1363 | "B" Camshaft Position Actuator Circuit Open, Low, High Bank2 |
DESCRIPTION
Refer to DTC P0010 (see pageClick here).
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P1362 | While engine is running, malfunction in rotation direction signal (VTD1) of camshaft timing control motor is detected for 3 seconds (1 trip detection logic) |
|
| P1363 | While engine is running, malfunction in rotation direction signal (VTD2) of camshaft timing control motor is detected for 3 seconds (1 trip detection logic) |
|
MONITOR DESCRIPTION
This DTC is output when a rotation direction signal malfunction is detected in the intake side camshaft timing control motor. While the engine is running, if a rotation direction signal (VTD) malfunction is detected, a DTC is output (2 trip detection logic).
When there is a malfunction, if the engine is idled for 30 seconds or the vehicle is driven in an urban area for 5 minutes, a DTC is output.
INSPECTION PROCEDURE
Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
PROCEDURE
INSPECT VVT RELAY (VVT LH, VVT RH)
Remove the VVT LH relay or VVT RH relay from the engine room No. 2 relay block.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE VOLTAGE)
Disconnect the E9 or E19 camshaft timing control motor.
Turn the engine switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | |||||||
|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR
Turn the engine switch off.
Disconnect the E9 or E19 camshaft timing control motor.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||
|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (CAMSHAFT TIMING CONTROL MOTOR - ECM)
Disconnect the E4 or E2 ECM connector.
Disconnect the E10 or E18 camshaft timing control motor connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | |||||||
|---|---|---|---|---|---|---|---|
|
| Standard resistance (Check for short) | |||||||
|---|---|---|---|---|---|---|---|
|
REPLACE CAMSHAFT TIMING CONTROL MOTOR (BANK 1 OR BANK 2)
Replace the camshaft timing control motor (see pageClick here).
CHECK WHETHER DTC OUTPUT RECURS
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the tester ON.
Clear the DTCs (see pageClick here).
Start the engine and allow the engine idle for 10 seconds or more.
Enter the following menus: Powertrain / Engine / DTC.
Read DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
REPAIR OR REPLACE HARNESS OR CONNECTOR
END
GO TO DTC CHARTClick here
REPLACE VVT RELAY (VVT LH, VVT RH)
REPLACE HARNESS OR CONNECTOR (VVT RELAY (VVT LH, VVT RH) - CAMSHAFT TIMING MOTOR)
INSPECT CAMSHAFT TIMING CONTROL MOTOR (BANK 1 OR BANK 2)
Check that the 3 bolts of the camshaft timing control motor are tightened securely.
| 21 N*m | 214 kgf*cm | 15 ft.*lbf |
REPAIR OR REPLACE HARNESS OR CONNECTOR (VVT RELAY (VVT LH, VVT RH) - CAMSHAFT TIMING CONTROL MOTOR)
CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the tester ON.
Clear the DTCs (see pageClick here).
Start the engine and allow the engine idle for 10 seconds or more.
Enter the following menus: Powertrain / Engine / DTC.
Read DTCs.
| Result | ||||||
|---|---|---|---|---|---|---|
|
TIGHTEN BOLTClick here