CAN COMMUNICATION SYSTEM (for LHD), Diagnostic DTC:U0233

DTC Code DTC Name
U0233 Lost Communication with Blind Spot Monitor Master Module

DESCRIPTION

DTC Code DTC Detection Condition Trouble Area
U0233 There is no communication from the blind spot monitor sensor LH.
  • Power source or inside of blind spot monitor sensor LH

  • Blind spot monitor sensor LH CAN branch wire or connector

  • Blind spot monitor sensor LH


WIRING DIAGRAM

A01H1GDE28

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Tech Tips

Operating the power switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.

PROCEDURE


  1. PRECAUTION

    Note

    After turning the power switch off, waiting time may be required before disconnecting the cable from the auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the auxiliary battery terminal notice before proceeding with work Click here.


    NEXT
  2. DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL


    1. Disconnect the cable from the negative (-) auxiliary battery terminal before measuring the resistances of the CAN main wire and the CAN branch wire.

      CAUTION:

      Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.

      Note

      When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.


    NEXT
  3. CHECK FOR OPEN IN CAN BUS WIRE (BLIND SPOT MONITOR SENSOR LH CAN BRANCH WIRE)


    1. A01GYLKE09
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Blind Spot Monitor Sensor LH)

      Disconnect the blind spot monitor sensor LH connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      m2-2 (CA1P) - m2-7 (CA1N) Power switch off 54 to 69 Ω

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BATTERY AND BODY GROUND)


    1. A01GYLKE10
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Blind Spot Monitor Sensor LH)

      Connect the cable to the negative (-) auxiliary battery terminal.

      Note

      When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      m2-5 (BLB) - Body ground Power switch on (IG) 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      m2-10 (BLGD) - Body ground Always Below 1 Ω

    NG
    OK