Click here

LUGGAGE COMPARTMENT DOOR CLOSER SWITCH INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT LUGGAGE COMPARTMENT DOOR CLOSER SWITCH


    1. A01GYEGE02

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Switch Condition Specified Condition
      3 (E) - 4 (CSW) Door control switch OFF 10 kΩ or higher
      3 (E) - 4 (CSW) Door control switch ON Below 1 Ω

      If the result is not as specified, replace the luggage compartment door closer switch.

      Table 1. Text in Illustration
      *a

      Component without harness connected:

      (Luggage Compartment Door Closer Switch)