OUTER REAR VIEW MIRROR GLASS INSPECTION


  1. INSPECT OUTER MIRROR LH


    1. A01GXPIE01
      Text in Illustration
      *a

      Component without harness connected

      (Outer Mirror LH)

      Check the mirror heater.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 25°C (77°F) 3.6 to 4.8 Ω

        If the result is not as specified, replace the outer mirror LH.

    2. Check the EC mirror operation.


      1. Connect 1.5 V dry-cell battery.

      2. A01H28GE01
        Text in Illustration
        *a

        Component without harness connected

        (Outer Mirror LH)

        Apply 1.5 V battery voltage and check the EC mirror operation.

        Note

        Do not apply a voltage of 1.5 V or higher.

        OK
        Measurement Connection Specified Condition

        1.5 V Battery positive (+) → Terminal 1

        1.5 V Battery negative (-) → Terminal 2

        Mirror surface becomes dark

        If the result is not as specified, replace the outer mirror LH.

    3. A01GZDEE01
      Text in Illustration
      *a

      Component without harness connected

      (Outer Mirror LH)

      *b EC Mirror Connector

      w/ Blind Spot Monitor:

      Check the operation of the blind spot monitor indicator.

      Note


      • Do not apply battery voltage to the EC mirror connector.

      • Do not apply a voltage of 7.5 V or higher.


      1. Connect 4 new 1.5 V dry-cell batteries in series.

      2. Apply 6 V battery voltage to the terminals of the connector, and check the blind spot monitor indicator condition.

        OK
        Tester Connection Specified Condition

        6 V Battery positive (+) → Terminal 1

        6 V Battery negative (-) → Terminal 2

        Blind spot monitor indicator comes on

        If the result is not as specified, replace the outer mirror LH.

  2. INSPECT OUTER MIRROR RH


    1. A01H0TNE01
      Text in Illustration
      *a

      Component without harness connected

      (Outer Mirror RH)

      Check the mirror heater.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 25°C (77°F) 3.6 to 4.8 Ω

        If the result is not as specified, replace the outer mirror RH.

    2. Check the EC mirror operation.


      1. Connect 1.5 V dry-cell battery.

      2. A01H09OE02
        Text in Illustration
        *a

        Component without harness connected

        (Outer Mirror RH)

        Apply 1.5 V battery voltage and check the EC mirror operation.

        Note

        Do not apply a voltage of 1.5 V or higher.

        OK
        Measurement Connection Specified Condition

        1.5 V Battery positive (+) → Terminal 1

        1.5 V Battery negative (-) → Terminal 2

        Mirror surface becomes dark

        If the result is not as specified, replace the outer mirror RH.

    3. A01GW69E01
      Text in Illustration
      *a

      Component without harness connected

      (Outer Mirror RH)

      *b EC Mirror Connector

      w/ Blind Spot Monitor:

      Check the operation of the blind spot monitor indicator.

      Note


      • Do not apply battery voltage to the EC mirror connector.

      • Do not apply a voltage of 7.5 V or higher.


      1. Connect 4 new 1.5 V dry-cell batteries in series.

      2. Apply 6 V battery voltage to the terminals of the connector, and check the blind spot monitor indicator condition.

        OK
        Tester Connection Specified Condition

        6 V Battery positive (+) → Terminal 1

        6 V Battery negative (-) → Terminal 2

        Blind spot monitor indicator comes on

        If the result is not as specified, replace the outer mirror RH.