POWER WINDOW CONTROL SYSTEM Rear Power Window RH Auto Up / Down Function does not Operate with Rear Power Window Switch RH

DESCRIPTION



WIRING DIAGRAM

A01GWUFE03

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK FOR DTC


    1. Check for DTCs.

      Result:
      Result Proceed to
      DTC is not output A
      B2311 is output B
      B2312 is output C
      B2313 is output D
      LIN communication system DTC is output E

    B
    C
    D
    E
    A
  2. CHECK MANUAL UP / DOWN FUNCTION


    1. Check that the manual UP/DOWN function using the power window regulator switch can operate the driver door power window.

      OK
      Manual UP/DOWN function operates normally.

    NG
    OK
  3. READ VALUE USING INTELLIGENT TESTER (REAR MOTOR RH)


    1. Use the Data List to check if the power window regulator motor is functioning properly.

      RR-Door Motor:
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      RR Door P/W Auto SW Rear power window RH remote auto UP/DOWN switch signal / ON or OFF

      ON: Rear power window RH remote auto UP/DOWN switch on master switch operated

      OFF: Rear power window RH switch on master switch not operated

      -
      OK
      Tester display changes normally when rear power window switch RH is operated.

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (REAR SWITCH RH - REAR MOTOR RH)


    1. A01GXH3E09

      Disconnect the O7 switch connector.

    2. Disconnect the O8 motor connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      O7-4 (AUTO) - O8-4 (AUTO) Always Below 1 Ω
      O7-4 (AUTO) or O8-4 (AUTO) - Body ground Always 10 kΩ or higher

    NG
    OK
  5. INSPECT REAR POWER WINDOW REGULATOR SWITCH ASSEMBLY (for RH)

    A01GXBQE19

    1. Remove the switch.

    2. Measure the resistance of the switch when the switch is operated.

      Standard resistance
      Tester Connection Switch Condition Specified Condition
      O7-4 (AUTO) - O7-5 (GND) AUTO UP/DOWN operation Below 1 Ω

    NG
    OK