DESCRIPTION
When the power switch is ON (IG) and window lock switch is off, the master switch sends remote UP/DOWN signal to each power window regulator motor via the LIN communication line.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
CHECK LIN COMMUNICATION SYSTEM
Check for LIN communication system DTCs related to the power window control system.
| Result | Proceed to |
|---|---|
| DTC is not output | A |
| DTC is output | B |
| B |
|
GO TO LIN COMMUNICATION SYSTEM Click here |
| A |
|
CHECK MASTER SWITCH ASSEMBLY (WINDOW LOCK SWITCH)
Turn the window lock switch off and operate the switches on the master switch. Check that the remote UP/DOWN function operates normally.
| OK |
|---|
| Remote UP/DOWN function operates normally. |
| NG |
|
REPLACE MASTER SWITCH ASSEMBLY Click here |
| OK |
|
END