HIGH PITCHED HORN INSPECTION


  1. INSPECT HIGH PITCHED HORN


    1. A01GY0XE01

      for Type A:

      Apply battery voltage and check operation of the horn, as shown in the table.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1

      Battery negative (-) → Body ground

      Horn sounds

      If the result is not as specified, replace the horn.

    2. A01GXIME02

      for Type B:

      Apply battery voltage and check operation of the horn, as shown in the table.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1

      Battery negative (-) → Body ground

      Horn sounds

      If the result is not as specified, replace the horn.