FRONT DOOR SPEAKER INSPECTION


  1. INSPECT FRONT NO. 1 SPEAKER ASSEMBLY


    1. for Standard:


      1. A01GYTBE04
        Text in Illustration
        *a

        Component without harness connected

        (Front No. 1 Speaker Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 Always Approx. 4 Ω

        If the result is not as specified, replace the front No. 1 speaker assembly.

    2. for 19 Speakers:


      1. A01GYTBE04
        Text in Illustration
        *a

        Component without harness connected

        (Front No. 1 Speaker Assembly)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 Always 11 to 13 Ω

        If the result is not as specified, replace the front No. 1 speaker assembly.