DESCRIPTION
The meter's ODO / TRIP display changes each time the trip switch is pressed.
Tech Tips
For more information about changing between displays, refer to the owner's manual.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (TRIP SWITCH)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Trip Reset SW | Trip switch (RESET switch) condition/ON or OFF | ON: Trip switch (ODO/TRIP switch) pushed OFF: Trip switch (ODO/TRIP switch) not pushed |
- |
| ODO/TRIP Change SW | Trip switch (ODO/TRIP switch) condition/ON or OFF | ON: Switch is pushed OFF: Switch is not pushed |
- |
| OK |
|---|
| Switch condition (ON/OFF) can be switched by actual operation. |
| NG |
|
INSPECT TRIP SWITCH Click here |
| OK |
|
REPLACE NO. 1 METER ECU Click here
INSPECT TRIP SWITCH
Remove the trip switch Click here.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE TRIP SWITCH Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (NO. 1 METER ECU - TRIP SWITCH AND BODY GROUND)
Disconnect the L124 meter connector.
Disconnect the L45 switch connector.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE NO. 1 METER ECU Click here