DESCRIPTION
This circuit is the power source circuit for the No. 1 meter ECU. This circuit provides 2 power source types: one is a constant power source mainly used as a backup power source, and the other is a power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU, however, it is also used for communication. If a voltage of 12 V is not applied to terminal IG2 when the power switch is on (IG), the indicator will not operate.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
INSPECT FUSE (D MPX-B 2, P-J/B)
Remove the D MPX-B 2 fuse from the main body ECU.
Remove the P-J/B fuse from the engine room No. 2 relay block.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||
|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE FUSE |
| OK |
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
Disconnect the L124 meter connector.
Measure the resistance and voltage according to the value(s) in the table below.
| Standard resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
| Standard voltage | ||||||||
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE NO. 1 METER ECU Click here