Click here

SHOULDER BELT ANCHORAGE SWITCH INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT HEIGHT ADJUSTABLE ANCHOR SWITCH (for LH Side)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (UL) - 4 (UP) UP Below 1 Ω
      2 (DW) - 4 (UP) UP 10 kΩ or higher
      2 (DW) - 3 (UL) DOWN Below 1 Ω
      3 (UL) - 4 (UP) DOWN 10 kΩ or higher

      If the result is not as specified, replace the height adjustable anchor switch.

  2. Click here

    INSPECT HEIGHT ADJUSTABLE ANCHOR SWITCH (for RH Side)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      2 (UP) - 3 (UL) UP Below 1 Ω
      2 (UP) - 4 (DW) UP 10 kΩ or higher
      3 (UL) - 4 (DW) DOWN Below 1 Ω
      2 (UP) - 3 (UL) DOWN 10 kΩ or higher

      If the result is not as specified, replace the height adjustable anchor switch.