AIRBAG SYSTEM, Diagnostic DTC:B1835/58, B1836/58, B1837/58, B1838/58

DTC Code DTC Name
B1835/58 Short in Curtain Shield Squib LH Circuit
B1836/58 Open in Curtain Shield Squib LH Circuit
B1837/58 Short to GND in Curtain Shield Squib LH Circuit
B1838/58 Short to B+ in Curtain Shield Squib LH Circuit

DESCRIPTION

The curtain shield squib LH circuit consists of the center airbag sensor assembly and the curtain shield airbag LH.

The circuit instructs the SRS to deploy when deployment conditions are met.

These DTCs are recorded when a malfunction is detected in the curtain shield squib LH circuit.

DTC Code Detection Condition Trouble Area
B1835/58

One of the following conditions is met:


  • The center airbag sensor assembly receives a line short circuit signal 5 times in the curtain shield squib LH circuit during the primary check.

  • Curtain shield squib LH malfunction

  • Center airbag sensor assembly malfunction


  • No. 2 floor wire

  • Curtain shield airbag assembly LH (Curtain shield squib LH)

  • Center airbag sensor assembly

B1836/58

One of the following conditions is met:


  • The center airbag sensor assembly receives an open circuit signal in the curtain shield squib LH circuit for 2 seconds.

  • Curtain shield squib LH malfunction

  • Center airbag sensor assembly malfunction


  • No. 2 floor wire

  • Curtain shield airbag assembly LH (Curtain shield squib LH)

  • Center airbag sensor assembly

B1837/58

One of the following conditions is met:


  • The center airbag sensor assembly receives a short circuit to ground signal in the curtain shield squib LH circuit for 0.5 seconds.

  • Curtain shield squib LH malfunction

  • Center airbag sensor assembly malfunction


  • No. 2 floor wire

  • Curtain shield airbag assembly LH (Curtain shield squib LH)

  • Center airbag sensor assembly

B1838/58

One of the following conditions is met:


  • The center airbag sensor assembly receives a short circuit to B+ signal in the curtain shield squib LH circuit for 0.5 seconds.

  • Curtain shield squib LH malfunction

  • Center airbag sensor assembly malfunction


  • No. 2 floor wire

  • Curtain shield airbag assembly LH (Curtain shield squib LH)

  • Center airbag sensor assembly

WIRING DIAGRAM

A01H1R1E44

INSPECTION PROCEDURE

Note


  • After turning the power switch OFF, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

  • When disconnecting the cable from the negative (-) auxiliary battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected Click here.

Tech Tips


  • Perform the simulation method by selecting "check mode" (signal check) with the intelligent tester Click here.

  • After selecting "check mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on various types of roads Click here.

PROCEDURE


  1. CHECK CURTAIN SHIELD AIRBAG LH (CURTAIN SHIELD SQUIB LH)

    A01GYNBE10

    1. Turn the power switch OFF.

    2. Disconnect the negative (-) terminal cable from the auxiliary battery, and wait for at least 90 seconds.

    3. Disconnect the connectors from the curtain shield airbag LH.

    4. Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.

      CAUTION:

      Never connect the tester to the curtain shield airbag LH (curtain shield squib LH) for measurement, as this may lead to a serious injury due to airbag deployment.

      Note


      • Do not forcibly insert SST into the terminals of the connector when connecting SST.

      • Insert SST straight into the terminals of the connector.

      SST
      09843-18061
    5. Connect the negative (-) terminal cable to the auxiliary battery, and wait for at least 2 seconds.

    6. Turn the power switch ON (IG), and wait for at least 60 seconds.

    7. Clear the DTCs Click here.

    8. Turn the power switch OFF.

    9. Turn the power switch ON (IG), and wait for at least 60 seconds.

    10. Check for DTCs Click here.

      OK
      DTC B1835, B1836, B1837 or B1838 is not output.

      Tech Tips

      Codes other than DTC B1835, B1836, B1837 and B1838 may be output at this time, but they are not related to this check.


    NG
    OK
  2. CHECK CONNECTOR


    1. Turn the power switch OFF.

    2. Disconnect the negative (-) terminal cable from the auxiliary battery, and wait for at least 90 seconds.

    3. Disconnect SST from connector C.

    4. Check that the No. 2 floor wire connectors (on the curtain shield airbag LH side) are not damaged.

      OK
      The lock button is not disengaged, or the claw of the lock is not deformed or damaged.

    NG
    OK
  3. CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD SQUIB LH CIRCUIT)

    A01GYS3E10

    1. Disconnect the connectors from the center airbag sensor assembly.

    2. Connect the negative (-) terminal cable to the auxiliary battery, and wait for at least 2 seconds.

    3. Turn the power switch ON (IG).

    4. Measure the voltage according to the value(s) in the table below.

      Standard voltage
      Tester Connection Switch Condition Specified Condition
      S24-1 (ICL+) - Body ground Power switch ON (IG) Below 1 V
      S24-2 (ICL-) - Body ground Power switch ON (IG) Below 1 V
    5. Turn the power switch OFF.

    6. Disconnect the negative (-) terminal cable from the auxiliary battery, and wait for at least 90 seconds.

    7. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      S24-1 (ICL+) - S24-2 (ICL-) Always Below 1 Ω
    8. Release the activation prevention mechanism built into connector B Click here.

    9. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      S24-1 (ICL+) - S24-2 (ICL-) Always 1 MΩ or higher
      S24-1 (ICL+) - Body ground Always 1 MΩ or higher
      S24-2 (ICL-) - Body ground Always 1 MΩ or higher

    NG
    OK
  4. CHECK CENTER AIRBAG SENSOR ASSEMBLY

    A01GWYLE27

    1. Connect the connectors to the curtain shield airbag LH and the center airbag sensor assembly.

    2. Connect the negative (-) terminal cable to the auxiliary battery, and wait for at least 2 seconds.

    3. Turn the power switch ON (IG), and wait for at least 60 seconds.

    4. Clear the DTCs Click here.

    5. Turn the power switch OFF.

    6. Turn the power switch ON (IG), and wait for at least 60 seconds.

    7. Check for DTCs Click here.

      OK
      DTC B1835, B1836, B1837 or B1838 is not output.

      Tech Tips

      Codes other than DTC B1835, B1836, B1837 and B1838 may be output at this time, but they are not related to this check.


    NG
    OK