INSPECT PRESSURE SWITCH
Install the manifold gauge set.
Disconnect the connector from the pressure switch.
| *a | Component without harness connected (Pressure Switch) |
| *b | Voltage |
| *c | Refrigerant Pressure |
Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 3, and the negative (-) lead to terminal 1.
Connect the voltmeter's positive (+) lead to terminal 2, and the negative (-) lead to terminal 1.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
If result is not as specified, replace the pressure switch.