PRESSURE SWITCH REMOVAL


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM


    1. Turn the power switch on (READY).

    2. Turn the A/C switch on.

    3. Operate the air conditioning with a set temperature of 25°C (77°F) and the blower at low for 10 minutes to circulate the refrigerant. This causes most of the compressor oil from the various components of the air conditioning system to collect in the air conditioning compressor.

    4. Turn the power switch off.

    5. Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.

  2. REMOVE FRONT BUMPER COVER

    Click here

  3. REMOVE AIR CONDITIONER PRESSURE SENSOR


    1. A01GWMF

      Disconnect the connector.

    2. Using a 27 mm deep socket wrench, remove the air conditioner pressure sensor.

    3. Remove the O-ring from the air conditioner pressure sensor.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent moisture and foreign matter from entering them.