AIR CONDITIONING SYSTEM, Diagnostic DTC:B1411/11

DTC Code DTC Name
B1411/11 Room Temperature Sensor Circuit

DESCRIPTION

The room temperature sensor for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner "AUTO" mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier. The room temperature sensor is integrated with the room humidity sensor.

DTC Code DTC Detection Condition Trouble Area
B1411/11 Open or short in room temperature sensor circuit
  • Room temperature sensor

  • Harness or connector between room temperature sensor and air conditioning amplifier

  • Air conditioning amplifier

WIRING DIAGRAM

A01H17CE01

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (ROOM TEMPERATURE SENSOR)


    1. Use the Data List to check if the room temperature sensor is functioning properly.

      Air Conditioner
      Tester Display Measurement Item / Range Normal Condition Diagnostic Note
      Room Temperature Sensor

      Room temperature sensor /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.05°F)

      Actual room temperature for front seat is displayed

      Open in circuit: -6.5°C (20.3°F)

      Short in circuit: 57.25°C (135.05°F)

      OK
      The display is as specified in the normal condition.

    NG
    OK
  2. INSPECT ROOM TEMPERATURE SENSOR

    A01GWZLE06

    1. Remove the room temperature sensor Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
      15°C (59°F) 2.45 to 2.88 kΩ
      20°C (68°F) 1.95 to 2.30 kΩ
      25°C (77°F) 1.60 to 1.80 kΩ
      30°C (86°F) 1.28 to 1.47 kΩ
      35°C (95°F) 1.00 to 1.22 kΩ
      40°C (104°F) 0.80 to 1.00 kΩ
      45°C (113°F) 0.65 to 0.85 kΩ
      50°C (122°F) 0.50 to 0.70 kΩ
      55°C (131°F) 0.44 to 0.60 kΩ
      60°C (140°F) 0.36 to 0.50 kΩ

      Note


      • Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Tech Tips

      As the temperature increases, the resistance decreases (see the graph).


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE - AIR CONDITIONING AMPLIFIER)

    A01GYT5E01

    1. Disconnect the L37 room temperature sensor connector.

    2. Disconnect the L77 air conditioning amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      L37-1(+) - L77-9 (TR) Always Below 1 Ω
      L37-2(-) - L77-32 (SG-1)
      L77-9 (TR) - Body ground Always 10 kΩ or higher
      L77-32 (SG-1) - Body ground

    NG
    OK