OIL PUMP RELAY INSPECTION


  1. INSPECT OIL PUMP RELAY


    1. A01H1OGE06

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage is applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.