BATTERY SMART UNIT REMOVAL


  1. REMOVE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY


    1. Remove the hybrid junction block assembly Click here.

  2. REMOVE BATTERY SMART UNIT

    A01GY2O

    CAUTION:

    Be sure to wear insulated gloves.


    1. Disconnect the 3 connectors from the battery smart unit.

    2. Remove the nut and battery smart unit.

      Note

      Insulate the connectors of the removed high voltage wires with insulating tape.