DESCRIPTION
Refer to the description for DTC P0C29-865 Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0C2E | 859 | Open or short to +B in the OPST (status signal line) circuit |
|
INSPECTION PROCEDURE
Note
If P0C2D-858 is also output, troubleshoot P0C2D-858 first.
PROCEDURE
CHECK HYBRID VEHICLE CONTROL ECU (CHECK WAVEFORM)
Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
| Item | Contents |
|---|---|
| Terminal | A76-33 (OPST) - A77-7 (E1) |
| Equipment Setting | 5 V/DIV., 5 ms./DIV. |
| Condition | Power switch on (IG) |
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
CHECK FOR INTERMITTENT PROBLEMS Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (OIL PUMP MOTOR CONTROLLER CONNECTOR)
Note
Before disconnecting the connectors, confirm that they are properly connected by checking that the locking claws are engaged and that the connectors do not pull out.
Check the connections of the oil pump motor controller connectors.
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
Tech Tips
For connector A, when connecting it, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
Check the connections of the hybrid vehicle control ECU connectors.
| OK |
|---|
| The connectors are connected securely and there are no contact problems. |
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK OIL PUMP MOTOR CONTROLLER
Turn the power switch off.
Disconnect connector A80 from the oil pump motor controller.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the oil pump motor controller connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| NG |
|
CHECK FUSIBLE LINK BLOCK ASSEMBLY (OIL PMP) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - OIL PUMP MOTOR CONTROLLER)
Turn the power switch off.
Disconnect connector A76 from the hybrid vehicle control ECU.
Disconnect connector A80 from the oil pump motor controller.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
Note
Turning the power switch on (IG) with the hybrid vehicle control ECU and oil pump motor controller connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard resistance (Check for short) | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HYBRID VEHICLE CONTROL ECU
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE HYBRID VEHICLE CONTROL ECU Click here |
| OK |
|
CHECK IF PART IS CORRECTLY GROUNDED
Measure the resistance according to the value(s) in the table below.
| Standard resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE OIL PUMP MOTOR CONTROLLER |
| OK |
|
REPLACE OIL PUMP MOTOR CONTROLLER Click here
CHECK FUSIBLE LINK BLOCK ASSEMBLY (OIL PMP)
Check if there is an open circuit in the fusible link (OIL PMP) in the engine room No. 1 junction block.
| OK |
|---|
| There is no open circuit in the fusible link (OIL PMP). |
| NG |
|
REPLACE FUSIBLE LINK BLOCK ASSEMBLY |
| OK |
|
CHECK HARNESS AND CONNECTOR
Turn the power switch off.
Remove the OIL PMP relay from the engine room No. 5 relay block.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Standard resistance (Check for short) | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK RELAY (OIL PMP)
Measure the resistance according to the value(s) in the table below.
| Standard resistance | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE RELAY (OIL PMP) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR
Turn the power switch off.
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HYBRID VEHICLE CONTROL ECU
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Standard voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - ENGINE ROOM NO. 5 RELAY BLOCK) Click here |
| OK |
|
REPLACE HYBRID VEHICLE CONTROL ECU Click here
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - ENGINE ROOM NO. 5 RELAY BLOCK)
Turn the power switch off.
Disconnect connector A76 from the hybrid vehicle control ECU.
Measure the resistance according to the value(s) in the table below.
| Standard resistance (Check for open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard resistance (Check for short) | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE HYBRID VEHICLE CONTROL ECU Click here
CHECK FOR INTERMITTENT PROBLEMS
Check for intermittent problems Click here.
| NG |
|
REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA |
| OK |
|
REPLACE HYBRID VEHICLE CONTROL ECU Click here