HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A01-725, P0A01-726

DTC Code DTC Name
P0A01-725 Motor Electronics Coolant Temperature Sensor Circuit Range / Performance
P0A01-726 Motor Electronics Coolant Temperature Sensor Circuit Range / Performance

DESCRIPTION

Refer to the description for DTC P0A02-719 Click here and DTC P0A93-346 Click here.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A01 725 Unusual sudden change in HV coolant temperature sensor output occurs and the offset continues, or unusual sudden change in HV coolant temperature sensor output occurs repeatedly.
  • Wire harness or connector

  • Inverter cooling system

  • No. 1 fan motor

  • Cooling fan ECU

  • Multiplex network front light ECU (front controller)

  • Fusible link block assembly

  • Fuse

  • Water pump with motor and bracket assembly

  • Inverter with converter assembly

  • Hybrid vehicle control ECU

P0A01 726

HV coolant temperature sensor output deviation

(Temperature calculated by ECU and actual temperature are different for 10 seconds or more.)

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK DTC OUTPUT (HV)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A01-725 or P0A01-726 only is output. A
      P0A93-346 is also output. B

    B
    A
  2. CHECK QUANTITY OF HV COOLANT


    1. Check the coolant level in the inverter reserve tank.

      A01H01QE01
    2. Check for coolant leaks.

      Result
      Result Proceed to
      Coolant leaks are not evident. A sufficient amount of coolant remains in the inverter reserve tank. A
      Coolant leaks are not evident. No coolant remains in the inverter reserve tank. B
      Coolant leaks are evident. C

      Tech Tips

      After repairing the coolant leaks and adding coolant, perform the "Activate the Water Pump" active test (HV ECU active test item) and the "Control the Electric Cooling Fan" active test (Engine ECU active test item) and make sure that there are no malfunctions.


    B
    C
    A
  3. CHECK COOLANT HOSE


    1. Check if the hoses of the cooling system are kinked or clogged.


    NG
    OK
  4. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (WATER PUMP)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

    4. Perform the "Activate the Water Pump" active test for at least 1 minute.

    5. Check that there are ripples in the coolant in the inverter reserve tank.

      A01H01QE01
      OK
      There are ripples in the coolant in the inverter reserve tank as long as the active test is being performed.

      Note

      In addition to the active test, the water pump with motor and bracket assembly will also operate with the power switch on (READY). However, the water pump with motor and bracket assembly will operate at low speed for 20 seconds after the power switch is turned on (READY).

      Tech Tips

      The water pump with motor and bracket assembly will also operate in inspection mode.


    NG
    OK
  5. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (COOLING FAN)


    1. Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.

    2. Perform the "Control the Electric Cooling Fan" active test.

      OK
      The cooling fan rotates.

    NG
    OK
  6. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    Note

    Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.


    1. Check the connection of the low voltage connector of the inverter with converter assembly.

      OK
      The connector is connected securely and there are no contact problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  7. INSPECT COOLING SYSTEM (FOR CLOGGING)


    1. Drain the inverter coolant Click here.

      Note

      Do not reuse the drained coolant because it may contain foreign objects.

      Tech Tips

      Drain the inverter coolant with the inverter reserve tank cap installed.

    2. Install the inverter reserve tank cap.

    3. Remove the drain plug.

    4. A01H22SE01

      Disconnect end A of the No. 3 inverter cooling hose.

      Note


      • Applied air pressure should be 59 kPa (0.6 kgf/cm2, 8.6 psi) or less.

      • Be careful when disconnecting the hose. Coolant may spill out of the hose.

    5. A01H0T5E01

      Cover the pipe shown in the illustration with packing tape.

    6. Using an air gun, apply air to the disconnected end of the hose to check for clogging in the coolant path.

      Note

      Be careful when applying air. Applying excessive air may cause coolant to overflow from the inverter reserve tank cap.

      OK
      Coolant and air come out from the drain.
    7. A01H22SE01

      Connect end A of the No. 3 inverter cooling hose and disconnect end B.

    8. A01GYTSE01

      Cover the pipe shown in the illustration with packing tape.

    9. Using an air gun, apply air to the disconnected end of the hose to check for clogging in the coolant path.

      Note


      • Applied air pressure should be 59 kPa (0.6 kgf/cm2, 8.6 psi) or less.

      • Be careful when applying air. Applying excessive air may cause coolant to overflow from the inverter reserve tank cap.

      OK
      Coolant and air come out from the drain.
      Result
      Result Proceed to
      OK (for LHD) A
      OK (for RHD) B
      NG C
    10. After this inspection, check for coolant leaks from the hose with the power switch on (READY).

      Note

      If leaks are found, replace the No. 3 inverter cooling hose and clamps.


    B
    C
    A
  8. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (WATER PUMP)


    1. A01H19R

      Connect the intelligent tester to the DLC3.

    2. Compress the inlet hose for the water pump with motor and bracket assembly several times.

    3. Turn the power switch on (IG) again.

    4. Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

    5. Perform the "Activate the Water Pump" active test for at least 1 minute.

    6. Check that there are ripples in the coolant in the inverter reserve tank.

      A01H01QE01
      OK
      There are ripples in the coolant in the inverter reserve tank as long as the active test is being performed.

      Note

      In addition to the active test, the water pump with motor and bracket assembly will also operate with the power switch on (READY). However, the water pump with motor and bracket assembly will operate at low speed for 20 seconds after the power switch is turned on (READY).

      Tech Tips

      The water pump with motor and bracket assembly will also operate in inspection mode.


    NG
    OK
  9. CHECK FUSE (INV W/P)


    1. A01GYN7E01

      Check if there is an open circuit in the fuse (INV W/P) in the engine room No. 2 relay block.

      OK
      There is no open circuit in the fuse (INV W/P).

      Tech Tips

      If the result is NG, replace the fuse (INV W/P) with a new one.


    NG
    OK
  10. CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR)


    1. A01GZ88

      Check the connection of the water pump with motor and bracket assembly connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  11. CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)


    1. Check the connections of the hybrid vehicle control ECU connectors.

      OK
      The connectors are connected securely and there are no contact problems.

    NG
    OK
  12. CHECK HARNESS AND CONNECTOR (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY)


    1. Disconnect connector A78 from the hybrid vehicle control ECU.

    2. Remove the fuse (INV W/P) from the engine room No. 2 relay block.

    3. Disconnect the water pump with motor and bracket assembly connector.

    4. Measure the resistance according to the value(s) in the table below.

      A01H19IE04
      Standard resistance (Check for open)
      Tester Connection Switch Condition Specified Condition
      A78-23 (IWP) - zA1-2 (SWP) Power switch off Below 1 Ω
      zA1-3 (GND) - Body ground Power switch off Below 1 Ω
      Engine Room No. 2 Relay Block INV W/P Fuse Terminal 2 - zA1-4 (+BWP) Power switch off Below 1 Ω
      Standard resistance (Check for short)
      Tester Connection Switch Condition Specified Condition
      A78-23 (IWP) or zA1-2 (SWP) - Body ground and other terminals Power switch off 10 kΩ or higher
      Engine Room No. 2 Relay Block INV W/P Fuse Terminal 2 or zA1-4 (+BWP) - Body ground and other terminals Power switch off 10 kΩ or higher

    NG
    OK
  13. CHECK WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY


    1. A01GWJ8E01

      Apply 12 V to terminal 2 of the INV W/P fuse holder of the engine room No. 2 relay block and check that the water pump operates.

      OK
      The water pump operates.

    NG
    OK
  14. CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR)


    1. A01GZ88

      Check the connection of the water pump with motor and bracket assembly connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  15. CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)


    1. Check the connections of the hybrid vehicle control ECU connectors.

      OK
      The connectors are connected securely and there are no contact problems.

    NG
    OK
  16. CHECK HARNESS AND CONNECTOR (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY)


    1. Disconnect connector A78 from the hybrid vehicle control ECU.

    2. Remove the fuse (INV W/P) from the engine room No. 2 relay block.

    3. Disconnect the water pump with motor and bracket assembly connector.

    4. Measure the resistance according to the value(s) in the table below.

      A01H19IE04
      Standard resistance (Check for open)
      Tester Connection Switch Condition Specified Condition
      A78-23 (IWP) - zA1-2 (SWP) Power switch off Below 1 Ω
      zA1-3 (GND) - Body ground Power switch off Below 1 Ω
      Engine room No. 2 relay block INV W/P fuse terminal 2 - zA1-4 (+BWP) Power switch off Below 1 Ω
      Standard resistance (Check for short)
      Tester Connection Switch Condition Specified Condition
      A78-23 (IWP) or zA1-2 (SWP) - Body ground and other terminals Power switch off 10 kΩ or higher
      Engine room No. 2 relay block INV W/P fuse terminal 2 or zA1-4 (+BWP) - Body ground and other terminals Power switch off 10 kΩ or higher

    NG
    OK
  17. CHECK WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY


    1. A01GWJ8E01

      Apply 12 V to terminal 2 of the INV W/P fuse holder of the engine room No. 2 relay block and check that the water pump operates.

      OK
      The water pump operates.

    NG
    OK