PURGE VALVE INSPECTION


  1. INSPECT PURGE VSV


    1. A01H1S6E01

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω
      1 - Body ground Always 10 MΩ or higher
      2 - Body ground

      If the result is not as specified, replace the purge VSV.

    2. Check operation of the purge VSV.


      1. A01GWFZE01

        Check that air does not flow from port E to port F.

      2. A01GZI4E01

        Apply battery voltage to the connector, and check the VSV operation.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Air flows from port E to port F

        If the result is not as specified, replace the purge VSV.