CANISTER INSPECTION


  1. INSPECT CANISTER

    A01GYDIE01

    1. Visually check the canister for cracks or damage.

      If cracks or damage are found, replace the canister.

    2. A01GYDIE03

      Blow 4 kPa (40.7 gf/cm2, 0.6 psi) of compressed air into port A and check that air flows without resistance from port B and port C.

      If the result is not as specified, replace the canister.

    3. Apply a vacuum of 2 kPa (15 mmHg, 0.591 in.Hg) to port A. Check that the vacuum does not decrease when ports B and C are closed, and check that the vacuum does not decrease when port B is released.

      If the result is not as specified, replace the canister.

  2. CLEAN FILTER IN CANISTER

    A01H1GAE02

    1. Clean the filter by blowing 4 kPa (40.7 gf/cm2, 0.6 psi) of compressed air into port A while holding port B closed.

      Tech Tips


      • Do not attempt to wash the canister.

      • No activated carbon should come out.