INTAKE AIR CONTROL VALVE ACTUATOR INSPECTION


  1. INSPECT INTAKE AIR CONTROL VALVE ACTUATOR

    A01H1XSE01

    1. Apply battery voltage to the connector, and check the operation of the actuator shaft.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1

      Battery negative (-) → Terminal 2

      Actuator shaft rotates to left

      Battery positive (+) → Terminal 2

      Battery negative (-) → Terminal 1

      Actuator shaft rotates to right

      Note

      Apply battery voltage for 10 seconds or less each time the inspection is performed.

      If the result is not as specified, replace the intake air control valve actuator.