2UR-FSE COOLING SERVICE DATA

Water inlet sub-assembly with thermostat
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10.0 mm (0.394 in.) or more at 95°C (203°F)
Cooling fan motor
Cooling fan motor When the battery is connected to the fan motor connector for Indication Mark M 14 to 18 A
for Indication Mark L 14.2 to 18.2 A
No. 2 Cooling fan motor When the battery is connected to the fan motor connector for Indication Mark M 14 to 18 A
for Indication Mark L 14.2 to 18.2 A
Radiator reservoir cap

Standard valve

(for brand-new cap)

93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 17.8 psi)

Minimum standard valve

(after using cap)

79 kPa (0.8 kgf/cm22, 11.4 psi)