DESCRIPTION
The rear blower with fan motor sub-assembly is operated by signals from the air conditioning amplifier. Rear blower motor speed signals are transmitted in accordance with changes in the duty ratio.
INSPECTION PROCEDURE
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER (REAR BLOWER WITH FAN MOTOR)
Select the Active Test, use the intelligent tester to generate a control command, and then check that the rear blower with fan motor sub-assembly operates (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Rear Blower Motor | Rear blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
| OK |
|---|
| Rear blower with fan motor sub-assembly operates and rear blower with fan motor sub-assembly speed changes. |
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - BATTERY AND BODY GROUND)
Disconnect the Q12 control connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to Blower Motor Control) |
INSPECT REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLY
Remove the rear blower with fan motor sub-assembly (Click here).
Apply battery voltage to the rear blower with fan motor sub-assembly and check the operation of the rear blower with fan motor sub-assembly.
| OK | ||||
|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - AIR CONDITIONING AMPLIFIER)
Disconnect the G24 amplifier connector.
Disconnect the Q12 control connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR CONTROL - REAR BLOWER WITH FAN MOTOR)
Disconnect the Q12 control connector.
Disconnect the Q14 motor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (REAR BLOWER WITH FAN MOTOR - BODY GROUND)
Disconnect the Q14 motor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *a | Front view of wire harness connector (to Rear Blower with Fan Motor Sub-assembly) |
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Remove the air conditioning amplifier assembly with its connectors still connected (Click here).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY
Remove the air conditioning amplifier assembly with its connectors still connected (Click here).
Using an oscilloscope, check the waveform.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G24-22 (BLWH) - G20-20 (RGND) |
| Tool Setting | 1 V/DIV., 500 μs/DIV. |
| Condition | Ignition switch ON Blower switch LO |
| OK |
|---|
| Waveform is as shown in the illustration. |
| *a | Component with harness connected (Air Conditioning Amplifier Assembly) |
Waveform varies with the blower level.
REPLACE BLOWER MOTOR CONTROL
Replace the blower motor control with a new or normally functioning one (Click here).
Operate the rear blower with fan motor sub-assembly to check that it functions properly.
| OK |
|---|
| Rear blower with fan motor sub-assembly operates normally. |
REPLACE REAR BLOWER WITH FAN MOTOR SUB-ASSEMBLYClick here
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here
END (BLOWER MOTOR CONTROL IS FAULTY)