AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System), Diagnostic DTC:B1417/17

Click here
Click here Click here
DTC Code DTC Name
B1417/17 Rear Evaporator Temperature Sensor Circuit
Click here

DESCRIPTION

The No. 2 air conditioning harness assembly (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the cooled air temperature that has passed through the evaporator and to control the rear air conditioning. It sends signals to the air conditioning amplifier assembly. The signals change in accordance with the resistance of the No. 2 air conditioning harness assembly (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier assembly applies a voltage (5 V) to the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) and reads voltage changes as the resistance of the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) changes. This sensor is used for frost prevention.

DTC Code DTC Detection Condition Trouble Area
B1417/17 Open or short in the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) circuit.
  • No. 2 air conditioning harness assembly (rear evaporator temperature sensor)

  • Harness or connector

  • Air conditioning amplifier assembly

Click here

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

Click here

PROCEDURE


  1. Click here

    READ VALUE USING INTELLIGENT TESTER (REAR EVAPORATOR TEMPERATURE SENSOR)


    1. Use the Data List to check if the rear evaporator temperature sensor is functioning properly (Click here).

      Table 1. Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Ambient Temp Sens (Rear)

      Rear evaporator temperature sensor /

      Min.: -29.7°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual rear evaporator temperature displayed

      Open in the circuit: -29.7°C (- 21.46°F).

      Short in the circuit: 59.55°C (139.19°F).

      OK
      The display is as specified in the normal condition column.
      Table 2. Result
      Result Proceed to
      OK (When troubleshooting according to problem symptoms table) A
      OK (When troubleshooting according to the DTC) B
      NG C

  2. Click here

    INSPECT NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (REAR EVAPORATOR TEMPERATURE SENSOR)


    1. A01DTO8E02

      Remove the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      7 (-) - 8 (+) -10°C (14°F) 7.30 to 9.10 kΩ
      -5°C (23°F) 5.65 to 6.95 kΩ
      0°C (32°F) 4.40 to 5.35 kΩ
      5°C (41°F) 3.40 to 4.15 kΩ
      10°C (50°F) 2.70 to 3.25 kΩ
      15°C (59°F) 2.14 to 2.58 kΩ
      20°C (68°F) 1.71 to 2.05 kΩ
      25°C (77°F) 1.38 to 1.64 kΩ
      30°C (86°F) 1.11 to 1.32 kΩ
      Table 3. Text in Illustration
      *a Sensing Portion
      *b Resistance
      *c Allowable Range
      *d Temperature
      Note:
      • Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

      • When measuring, the sensor temperature must be the same as the ambient temperature.

      Tip:

      As the temperature increases, the resistance decreases (refer to the graph).


  3. Click here

    CHECK HARNESS AND CONNECTOR (REAR EVAPORATOR TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)


    1. Disconnect the Q13 harness connector.

    2. Disconnect the G24 amplifier connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Q13-8 (+) - G24-4 (TEC) Always Below 1 Ω
      Q13-7 (-) - G24-19 (SGND) Always Below 1 Ω
      Q13-8 (+) - Body ground Always 10 kΩ or higher
      Q13-7 (-) - Body ground Always 10 kΩ or higher

  4. Click here

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLEClick here

  5. Click here

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here

  6. Click here

    REPLACE NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (REAR EVAPORATOR TEMPERATURE SENSOR)Click here

  7. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  8. Click here

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLYClick here