DESCRIPTION
The No. 2 air conditioning harness assembly (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the cooled air temperature that has passed through the evaporator and to control the rear air conditioning. It sends signals to the air conditioning amplifier assembly. The signals change in accordance with the resistance of the No. 2 air conditioning harness assembly (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier assembly applies a voltage (5 V) to the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) and reads voltage changes as the resistance of the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) changes. This sensor is used for frost prevention.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1417/17 | Open or short in the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) circuit. |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (REAR EVAPORATOR TEMPERATURE SENSOR)
Use the Data List to check if the rear evaporator temperature sensor is functioning properly Click here.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Ambient Temp Sens (Rear) | Rear evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual rear evaporator temperature displayed | Open in the circuit: -29.7°C (- 21.46°F). Short in the circuit: 59.55°C (139.19°F). |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table) | A |
| OK (When troubleshooting according to the DTC) | B |
| NG | C |
| B |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| C |
|
INSPECT NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (REAR EVAPORATOR TEMPERATURE SENSOR) Click here |
| A |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
INSPECT NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (REAR EVAPORATOR TEMPERATURE SENSOR)
| *a | Sensing Portion |
| *b | Resistance |
| *c | Allowable Range |
| *d | Temperature |
Remove the No. 2 air conditioning harness assembly (rear evaporator temperature sensor) Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tech Tips
As the temperature increases, the resistance decreases (refer to the graph).
| NG |
|
REPLACE NO. 2 AIR CONDITIONING HARNESS ASSEMBLY (REAR EVAPORATOR TEMPERATURE SENSOR) Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (REAR EVAPORATOR TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
Disconnect the Q13 harness connector.
Disconnect the G24 amplifier connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here