Click here

LUMBAR SWITCH (for Power Seat) INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT LUMBAR SWITCH ASSEMBLY (for LHD)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      3 (H) - 5 (B) Hold Below 1 Ω
      1 (R) - 2 (E)
      2 (E) - 3 (H) Off
      2 (E) - 1 (R)
      2 (E) - 3 (H) Release
      1 (R) - 5 (B)

      If the result is not as specified, replace the lumbar switch.

      Table 1. Text in Illustration
      *1 Hold Switch
      *2 Release Switch
      *a

      Component without harness connected

      (Lumbar Switch)

  2. Click here

    INSPECT LUMBAR SWITCH ASSEMBLY (for RHD)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 (H) - 5 (B) Hold Below 1 Ω
      3 (R) - 2 (E)
      1 (H) - 2 (E) Off
      3 (R) - 2 (E)
      1 (H) - 2 (E) Release
      3 (R) - 5 (B)

      If the result is not as specified, replace the lumbar switch.

      Table 2. Text in Illustration
      *1 Hold Switch
      *2 Release Switch
      *a

      Component without harness connected

      (Lumbar Switch)