CHECK FRONT POWER SEAT SWITCH (for LHD)
Disconnect the b4 and b5 connectors from the front power seat switch LH.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| b4-1 (GND2) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| b4-2 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| b4-6 (+B2) - b4-1 (GND2) | SB - W-B | Power source | Always | 11 to 14 V |
| b4-7 (+B) - b4-2 (GND) | W - W-B | Power source | Always | 11 to 14 V |
| b5-12 (SYSB) - b4-2 (GND) | P - W-B | System power source | Always | 11 to 14 V |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the b4 and b5 switch connectors.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| b4-3 (SLD+) - b4-2 (GND) | L - W-B | Sliding motor signal (forward) | Slide switch off | Below 1 V |
| Slide switch on (Forward) | 11 to 14 V | |||
| b4-4 (SLD-) - b4-2 (GND) | GR - W-B | Sliding motor signal (rearward) | Slide switch off | Below 1 V |
| Slide switch on (Rearward) | 11 to 14 V | |||
| b4-5 (FRV-) - b4-2 (GND) | R - W-B | Front vertical motor signal (downward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Downward) | 11 to 14 V | |||
| b4-8 (FRV+) - b4-2 (GND) | B - W-B | Front vertical motor signal (upward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Upward) | 11 to 14 V | |||
| b4-9 (RCL+) - b4-2 (GND) | P - W-B | Reclining motor signal (forward) | Reclining switch off | Below 1 V |
| Reclining switch on (Forward) | 11 to 14 V | |||
| b4-11 (RCL-) - b4-2 (GND) | LG - W-B | Reclining motor signal (rearward) | Reclining switch off | Below 1 V |
| Reclining switch on (Rearward) | 11 to 14 V | |||
| b4-10 (LFT+) - b4-2 (GND) | V - W-B | Lifter motor signal (upward) | Lifter switch off | Below 1 V |
| Lifter switch on (Upward) | 11 to 14 V | |||
| b4-12 (LFT-) - b4-2 (GND) | G - W-B | Lifter motor signal (downward) | Lifter switch off | Below 1 V |
| Lifter switch on (Downward) | 11 to 14 V | |||
| b5-1 (SGND) - b4-2 (GND) | BR - W-B | Ground | Always | Below 1 Ω |
| b5-3 (SSFV) - b5-1 (SGND) | R - BR | Front vertical position signal | Front vertical function operating | 4.5 to 4.8 V |
| b5-4 (SSRL) - b5-1 (SGND) | P - BR | Lifter position signal | Lifter function operating | 4.5 to 4.8 V |
| b5-5 (SSRS) - b5-1 (SGND) | G- BR | Slide position signal | Slide function operating | 4.5 to 4.8 V |
| b5-11 (SSRR) - b5-1 (SGND) | V - BR | Reclining position signal | Reclining function operating | 4.5 to 4.8 V |
If the result is not as specified, the front power seat switch may have a malfunction.
CHECK FRONT POWER SEAT SWITCH (for RHD)
Disconnect the a4 and a5 connectors from the front power seat switch RH.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| a4-1 (GND2) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| a4-2 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| a4-6 (+B2) - a4-1 (GND2) | SB - W-B | Power source | Always | 11 to 14 V |
| a4-7 (+B) - a4-2 (GND) | W - W-B | Power source | Always | 11 to 14 V |
| a5-12 (SYSB) - a4-2 (GND) | P - W-B | System power source | Always | 11 to 14 V |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the a4 and a5 switch connectors.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| a4-3 (SLD+) - a4-2 (GND) | L - W-B | Sliding motor signal (forward) | Slide switch off | Below 1 V |
| Slide switch on (Forward) | 11 to 14 V | |||
| a4-4 (SLD-) - a4-2 (GND) | GR - W-B | Sliding motor signal (rearward) | Slide switch off | Below 1 V |
| Slide switch on (Rearward) | 11 to 14 V | |||
| a4-5 (FRV-) - a4-2 (GND) | R - W-B | Front vertical motor signal (downward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Downward) | 11 to 14 V | |||
| a4-8 (FRV+) - a4-2 (GND) | B - W-B | Front vertical motor signal (upward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Upward) | 11 to 14 V | |||
| a4-9 (RCL+) - a4-2 (GND) | P - W-B | Reclining motor signal (forward) | Reclining switch off | Below 1 V |
| Reclining switch on (Forward) | 11 to 14 V | |||
| a4-11 (RCL-) - a4-2 (GND) | LG - W-B | Reclining motor signal (rearward) | Reclining switch off | Below 1 V |
| Reclining switch on (Rearward) | 11 to 14 V | |||
| a4-10 (LFT+) - a4-2 (GND) | V - W-B | Lifter motor signal (upward) | Lifter switch off | Below 1 V |
| Lifter switch on (Upward) | 11 to 14 V | |||
| a4-12 (LFT-) - a4-2 (GND) | G - W-B | Lifter motor signal (downward) | Lifter switch off | Below 1 V |
| Lifter switch on (Downward) | 11 to 14 V | |||
| a5-1 (SGND) - a4-2 (GND) | BR - W-B | Ground | Always | Below 1 Ω |
| a5-3 (SSFV) - a5-1 (SGND) | R - BR | Front vertical position signal | Front vertical function operating | 4.5 to 4.8 V |
| a5-4 (SSRL) - a5-1 (SGND) | P - BR | Lifter position signal | Lifter function operating | 4.5 to 4.8 V |
| a5-5 (SSRS) - a5-1 (SGND) | G - BR | Slide position signal | Slide function operating | 4.5 to 4.8 V |
| a5-11 (SSRR) - a5-1 (SGND) | V - BR | Reclining position signal | Reclining function operating | 4.5 to 4.8 V |
If the result is not as specified, the front power seat switch may have a malfunction.
CHECK DRIVER SIDE JUNCTION BLOCK ASSEMBLY AND MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
| *A | for LHD | *B | for RHD |
Remove the main body ECU Click here.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A-30 (BECU) - Body ground | - | Power source | Always | 11 to 14 V |
| A-32 (IG) - Body ground | - | Power source (IG) | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| A-11 (GND) - Body ground | - | Body ground | Always | Below 1 Ω |
| G63-3 (GND2) - Body ground | W-B - Body ground | Body ground | Always | Below 1 Ω |
If the result is not as specified, there may be a malfunction on the wire harness side.
Install the main body ECU Click here.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G63-25 (M1) - Body ground | SB - Body ground | Memory switch M1 signal | Memory switch M1 off | Pulse generation (See waveform 1 or 2) |
| Memory switch M1 on | Below 1 V | |||
| G63-26 (MM) - Body ground | LG - Body ground | Memory switch SET signal | Memory switch SET off | Pulse generation (See waveform 1 or 2) |
| Memory switch SET on | Below 1 V | |||
| G63-27 (M2) - Body ground | V - Body ground | Memory switch M2 signal | Memory switch M2 off | Pulse generation (See waveform 1 or 2) |
| Memory switch M2 on | Below 1 V | |||
| 2I-27 (FLCY) - Body ground*1 | R - Body ground | Front door courtesy light switch LH signal | Front door LH closed | 11 to 14 V |
| Front door LH open | Below 1 V | |||
| 2H-26 (FRCY) - Body ground*2 | B - Body ground | Front door courtesy light switch RH signal | Front door RH closed | 11 to 14 V |
| Front door RH open | Below 1 V |
*1: for LHD
*2: for RHD
Using an oscilloscope, check waveform 1.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G63-25 (M1) - Body ground G63-26 (MM) - Body ground G63-27 (M2) - Body ground |
| Tool Setting | 5 V/DIV., 20 ms/DIV. |
| Condition | Memory switch M1 off Memory switch SET off Memory switch M2 off |
Using an oscilloscope, check waveform 2.
| Item | Content |
|---|---|
| Terminal No. (Symbol) | G63-25 (M1) - Body ground G63-26 (MM) - Body ground G63-27 (M2) - Body ground |
| Tool Setting | 5 V/DIV., 20 ms/DIV. |
| Condition | Memory switch M1 off Memory switch SET off Memory switch M2 off |