TRIP SWITCH INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT TRIP SWITCH (w/o TAIL Cancel Switch)


    1. Inspect the light control rheostat.


      1. A01DUC8E01

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Table 1. for LHD
        Tester Connection Switch Condition Specified Condition
        5 (T) - 1 (E) Always 8 to 12 kΩ
        7 (RV) - 1 (E) Light control rheostat fully turned right → Light control rheostat fully turned left Below 100 Ω → 8 to 12 kΩ
        Table 2. for RHD
        Tester Connection Switch Condition Specified Condition
        8 (T) - 4 (E) Always 8 to 12 kΩ
        6 (RV) - 4 (E) Light control rheostat fully turned right → Light control rheostat fully turned left Below 100 Ω → 8 to 12 kΩ
    2. Inspect the ODO/TRIP switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Table 3. for LHD
        Tester Connection Switch Condition Specified Condition
        4 (A/B) - 1 (E) ODO/TRIP switch on (Pushed) Below 1 Ω
        ODO/TRIP switch off (Not pushed) 1 MΩ or higher
        Table 4. for RHD
        Tester Connection Switch Condition Specified Condition
        1 (A/B) - 4 (E) ODO/TRIP switch on (Pushed) Below 1 Ω
        ODO/TRIP switch off (Not pushed) 1 MΩ or higher

        If the result is not as specified, replace the rheostat.

  2. Click here

    INSPECT TRIP SWITCH (w/ TAIL Cancel Switch)


    1. Inspect the light control rheostat.


      1. A01DTIWE01

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Table 5. for LHD
        Tester Connection Switch Condition Specified Condition
        5 (T) - 6 (TC) TAIL cancel switch off → on 1 MΩ or higher → Below 100 Ω
        5 (T) - 1 (E) Always 8 to 12 kΩ
        7 (RV) - 1 (E) Light control rheostat fully turned right → Light control rheostat fully turned left Below 100 Ω → 8 to 12 kΩ
        Table 6. for RHD
        Tester Connection Switch Condition Specified Condition
        7 (TC) - 8 (T) TAIL cancel switch off → on 1 MΩ or higher → Below 1 Ω
        8 (T) - 4 (E) Always 8 to 12 kΩ
        6 (RV) - 4 (E) Light control rheostat fully turned right → Light control rheostat fully turned left Below 100 Ω → 8 to 12 kΩ
    2. Inspect the ODO/TRIP switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Table 7. for LHD
        Tester Connection Switch Condition Specified Condition
        4 (A/B) - 1 (E) ODO/TRIP switch on (Pushed) Below 1 Ω
        ODO/TRIP switch off (Not pushed) 1 MΩ or higher
        Table 8. for RHD
        Tester Connection Switch Condition Specified Condition
        1 (A/B) - 4 (E) ODO/TRIP switch on (Pushed) Below 1 Ω
        ODO/TRIP switch off (Not pushed) 1 MΩ or higher

        If the result is not as specified, replace the rheostat.