METER / GAUGE SYSTEM Meter Illumination does not Dim at Night

DESCRIPTION

If the dimmer switch is turned to TAIL, HEAD or AUTO, the main body ECU sends a TAIL relay signal, panel light illumination signal, panel relay signal, and TAIL cancel OFF signal to the combination meter. Then the meter dims.

Tech Tips

TAIL cancel switch: When the headlights are illuminated and the TAIL cancel switch is turned ON, the meter does not dim.

WIRING DIAGRAM

A01DUSPE01

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK CAN COMMUNICATION SYSTEM


    1. Check if a CAN communication DTC is output.


      1. for LHD with Entry and Start System Click here.

      2. for LHD without Entry and Start System Click here.

      3. for RHD with Entry and Start System Click here.

      4. for RHD without Entry and Start System Click here.

        Result
        Result Proceed to
        CAN communication system DTC is not output A
        CAN communication system DTC is output (for LHD with Entry and Start System) B
        CAN communication system DTC is output (for LHD without Entry and Start System) C
        CAN communication system DTC is output (for RHD with Entry and Start System) D
        CAN communication system DTC is output (for RHD without Entry and Start System) E

    B
    C
    D
    E
    A
  2. READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT)


    1. Operate the intelligent tester according to the display and select Data List Click here.

      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Tail Cancel SW* TAIL cancel switch condition/ON or OFF

      ON: TAIL cancel switch ON

      OFF: TAIL cancel switch OFF

      -
      Rheostat value Light control rheostat switch input/Min.: 0, Max.: 100 Light control rheostat switch is fully turned left (0) → fully turned right (100) Unit: %

      • *: w/ TAIL Cancel Switch

      OK
      Light brightness can be changed within specified range by manual operation.

    NG
    OK
  3. INSPECT LIGHT CONTROL RHEOSTAT


    1. Inspect the light control rheostat. (w/o TAIL cancel switch)

      A01DNDUE01

      1. Remove the light control rheostat Click here.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        for LHD
        Tester Connection Switch Condition Specified Condition
        5 (T) - 1 (E) Always 8 to 12 kΩ
        7 (RV) - 1 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ
        for RHD
        Tester Connection Switch Condition Specified Condition
        8 (T) - 4 (E) Always 8 to 12 kΩ
        6 (RV) - 4 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ
    2. Inspect the light control rheostat. (w/ TAIL cancel switch)

      A01DTS9E01

      1. Remove the light control rheostat Click here.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        for LHD
        Tester Connection Switch Condition Specified Condition
        5 (T) - 6 (TC) TAIL cancel switch off → on 1 MΩ or higher → Below 1 Ω
        5 (T) - 1 (E) Always 8 to 12 kΩ
        7 (RV) - 1 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ
        for RHD
        Tester Connection Switch Condition Specified Condition
        8 (T) - 7 (TC) TAIL cancel switch off → on 1 MΩ or higher → Below 1 Ω
        8 (T) - 4 (E) Always 8 to 12 kΩ
        6 (RV) - 4 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)


    1. Disconnect the G6 meter connector.

    2. Disconnect the G16 rheostat connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      G6-6 (SW1) - G16-5 (T) Always Below 1 Ω
      G6-7 (SW2) - G16-7 (RV)
      G6-22 (SW3) - G16-1 (E)
      G6-10 (TC) - G16-6 (TC)*
      for RHD
      Tester Connection Condition Specified Condition
      G6-6 (SW1) - G16-8 (T) Always Below 1 Ω
      G6-7 (SW2) - G16-6 (RV)
      G6-22 (SW3) - G16-4 (E)
      G6-10 (TC) - G16-7 (TC)*

      • *: w/ TAIL Cancel Switch


    NG
    OK