METER / GAUGE SYSTEM Operating Light Control Rheostat does not Change Light Brightness

DESCRIPTION

When the light control rheostat knob is turned right, the combination meter and vehicle interior illumination will become brighter. When the light control rheostat knob is turned left, the combination meter and vehicle illumination will dim.

WIRING DIAGRAM

A01DR8NE01

INSPECTION PROCEDURE

PROCEDURE


  1. READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT)


    1. Operate the intelligent tester according to the display and select Data List Click here.

      Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Tail Cancel SW* TAIL cancel switch condition/ON or OFF

      ON: TAIL cancel switch ON

      OFF: TAIL cancel switch OFF

      -
      Rheostat value Light control rheostat switch input/Min.: 0, Max.: 100 Light control rheostat switch is fully turned left (0) → fully turned right (100) Unit: %

      • *: w/ TAIL Cancel Switch

      OK
      Light brightness can be changed within specified range by manual operation.

    NG
    OK
  2. INSPECT LIGHT CONTROL RHEOSTAT


    1. Inspect the light control rheostat. (w/o TAIL Cancel Switch)

      A01DUC8E01

      1. Remove the light control rheostat Click here.

      2. Measure the resistance according to the table below.

        Standard Resistance
        for LHD
        Tester Connection Switch Condition Specified Condition
        5 (T) - 1 (E) Always 8 to 12 kΩ
        7 (RV) - 1 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ
        for RHD
        Tester Connection Switch Condition Specified Condition
        8 (T) - 4 (E) Always 8 to 12 kΩ
        6 (RV) - 4 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ
    2. Inspect the light control rheostat. (w/ TAIL Cancel Switch)

      A01DTIWE01

      1. Remove the light control rheostat Click here.

      2. Measure the resistance according to the table below.

        Standard Resistance
        for LHD
        Tester Connection Switch Condition Specified Condition
        5 (T) - 6 (TC) TAIL cancel switch off → on 1 MΩ or higher → Below 1 Ω
        5 (T) - 1 (E) Always 8 to 12 kΩ
        7 (RV) - 1 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ
        for RHD
        Tester Connection Switch Condition Specified Condition
        8 (T) - 7 (TC) TAIL cancel switch off → on 1 MΩ or higher → Below 1 Ω
        8 (T) - 4 (E) Always 8 to 12 kΩ
        6 (RV) - 4 (E) Light control rheostat fully turned right → fully turned left Below 100 Ω → 8 to 12 kΩ

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)


    1. Disconnect the G6 meter connector.

    2. Disconnect the G16 rheostat connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Condition Specified Condition
      G6-10 (TC) - G16-6 (TC)* Always Below 1 Ω
      G6-6 (SW1) - G16-5 (T)
      G6-7 (SW2) - G16-7 (RV)
      G6-22 (SW3) - G16-1 (E)
      for RHD
      Tester Connection Condition Specified Condition
      G6-10 (TC) - G16-7 (TC)* Always Below 1 Ω
      G6-6 (SW1) - G16-8 (T)
      G6-7 (SW2) - G16-6 (RV)
      G6-22 (SW3) - G16-4 (E)

      • *: w/ TAIL Cancel Switch


    NG
    OK
  4. REPLACE COMBINATION METER ASSEMBLY


    1. Replace the combination meter assembly with a new or normally operating one. Perform an operation inspection.

      OK
      Combination meter assembly operates normally.

    NG
    OK