DESCRIPTION
The meter CPU receives ODO/TRIP change switch signal from the light control rheostat via the direct line.
Tech Tips
The whole light control rheostat should be replaced if the ODO/TRIP switch is malfunctioning.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (ODO/TRIP CHANGE SW)
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| ODO/TRIP Change SW | ODO/TRIP change switch/OFF or ON | OFF: ODO/TRIP change switch released | - |
| ON: ODO/TRIP change switch pressed |
| OK |
|---|
| The value displayed on the intelligent tester changes with the actual ODO/TRIP change switch operation. |
| NG |
|
INSPECT TRIP SWITCH Click here |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here
INSPECT TRIP SWITCH
Disconnect the G16 trip switch connector.
Inspect the ODO/TRIP switch
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
|
| NG |
|
REPLACE TRIP SWITCH Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - TRIP SWITCH)
Disconnect the G6 meter connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
|||||||||
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here