DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE AIR CLEANER AND HOSE
Detach the 3 clamps and disconnect the mass air flow meter connector.
Detach the 4 clamps.
Loosen the hose clamp and remove the air cleaner and hose.
REMOVE FAN AND GENERATOR V BELT
Use the hexagonal part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the V belt. Then remove the V belt.
Note
When removing the V belt, do not use the bolt of the idle pulley.
Tech Tips
After removing the drive belt, move the tensioner upward to the maximum amount.
REMOVE GENERATOR ASSEMBLY
Disconnect the generator connector.
Remove the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Remove the 3 bolts and generator.