CRAWL SWITCH INSPECTION


  1. INSPECT CRAWL CONTROL SWITCH


    1. A01DPD6E01
      Text in Illustration
      *a LO
      *b LO / MEDIUM
      *c MEDIUM
      *d MEDIUM / HI
      *e HI
      A01DOVRE01
      Text in Illustration
      *a

      Component without harness connected

      (Center Cluster Module switch (Crawl Control Switch))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      17 (ECU) - 24 (E) LO Below 1 Ω
      18 (UP) - 24 (E)
      19 (DN) - 24 (E) 10 kΩ or higher
      17 (ECU) - 24 (E) LO / MEDIUM Below 1 Ω
      18 (UP) - 24 (E) 10 kΩ or higher
      19 (DN) - 24 (E)
      17 (ECU) - 24 (E) MEDIUM 10 kΩ or higher
      18 (UP) - 24 (E)
      19 (DN) - 24 (E)
      17 (ECU) - 24 (E) MEDIUM / HI 10 kΩ or higher
      18 (UP) - 24 (E)
      19 (DN) - 24 (E) Below 1 Ω
      17 (ECU) - 24 (E) HI 10 kΩ or higher
      18 (UP) - 24 (E) Below 1 Ω
      19 (DN) - 24 (E)
      21 (FRB) - 24 (E) ON/OFF: Pressed Below 1 Ω
      ON/OFF: Not pressed 10 kΩ or higher

      If the result is not as specified, replace the crawl control switch.