DESCRIPTION
The slip indicator light blinks during VSC, TRC, crawl control or multi-terrain select control operation. When the system fails, the slip indicator light comes on to warn the driver.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
When replacing the master cylinder solenoid, perform calibration Click here.
PROCEDURE
CHECK DTC
Check for DTCs Click here.
| Result | Proceed to |
|---|---|
| DTC is not output | A |
| DTC is output | B |
| B |
|
REPAIR CIRCUITS INDICATED BY OUTPUT DTCS Click here |
| A |
|
CHECK CAN COMMUNICATION LINE
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Select CAN Bus Check from the System Selection Menu screen and follow the prompts on the screen to inspect the CAN bus (for LHD: Click here, for RHD: Click here.
| OK |
|---|
| CAN Bus Check indicates no malfunctions in CAN communication. |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
| B |
|
GO TO CAN COMMUNICATION SYSTEM (HOW TO PROCEED WITH TROUBLESHOOTING) Click here |
| C |
|
GO TO CAN COMMUNICATION SYSTEM (HOW TO PROCEED WITH TROUBLESHOOTING) Click here |
| A |
|
READ VALUE USING INTELLIGENT TESTER (SLIP INDICATOR LIGHT)
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Chassis / ABS/VSC/TRC / Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Slip Indicator Light | Slip indicator light/ ON or OFF | ON: Indicator light on OFF: Indicator light off |
- |
When performing the Slip Indicator Light Active Test, check Slip Indicator Light in the Data List Click here.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Slip Indicator Light | Slip indicator light | Indicator light ON/OFF | Observe the combination meter. |
| Result | Proceed to | |
|---|---|---|
| Data List Display | Data List Display when Performing Active Test ON/OFF Operation | |
| ON | Changes between ON and OFF | A |
| Does not change between ON and OFF (for LHD) | B | |
| Does not change between ON and OFF (for RHD) | C | |
| OFF | Changes between ON and OFF | A |
| Does not change between ON and OFF (for LHD) | B | |
| Does not change between ON and OFF (for RHD) | C | |
| B |
|
REPLACE MASTER CYLINDER SOLENOID Click here |
| C |
|
REPLACE MASTER CYLINDER SOLENOID Click here |
| A |
|
GO TO METER / GAUGE SYSTEM (HOW TO PROCEED WITH TROUBLESHOOTING) Click here